Page 263 - Know and Understand Centrifugal Pumps
P. 263

Know and Understand Centrifugal Pumps
                  Concentric reducer "J -
                                INCORRECT













                                  -
                                 CORRECT
                                 CORRECT









        Figure 17-17

          Use an eccentric pipe reducer to connect to the pump suction nozzle
          (Figure 17-1 7).
          Don't  use  flange  bolts  to unite  misaligned piping  to the  pump.  This
          damages the flange faces and stresses the pump casing (Figure 17-18).










                      INCORRECT                    CORRECT








        Fiaure 17-18











            246
   258   259   260   261   262   263   264   265   266   267   268