Page 258 - Know and Understand Centrifugal Pumps
P. 258

Pump Piping









                                           -

                                              n                    PREFERRED



                                                                   DISCHARGE
                                                                    POSITION




                                         BAFFLE STOPS     BU~BLES
                                         TURBULENCE
                                         AND BUBBLES
       Figure 17-7

         A  submerged  in-flow  pipe  and  tank  baffles  prevent  turbulence  and
         bubbles frgm entering thhe suction piping (Figuk 17-7).













                            f







       Figure 17-8
       -

         The suction  bell  reduces entrance losses and helps to prevent vortices.
         If you  use  a basket  strainer,  the  screen area should  be  four times the
         area of the entrance pipe. Avoid tight mesh  screens because they clog
         quickly (Figure 17-8).