Page 65 - Low Temperature Energy Systems with Applications of Renewable Energy
P. 65
54 Low-Temperature Energy Systems with Applications of Renewable Energy
3
Table 2.3 Water consumption (m /h) for optimal distance (m) between a producing and
disposal well with 20% water-bearing formation porosity.
Water- Optimal distance between wells, m
bearing No. of
bed operating
thickness, days per
m year 2.3 4.6 9.2 13.8 18.4 23 46 115 230
3 100 35 48 69 85 99 111
140 39 54 77 94 110 122
210 44 61 88 109 127 144
280 50 68 100 124 145 125
6 100 30 41 59 72 84 94
140 33 48 67 82 96 108
210 39 54 77 95 111 124
280 44 61 87 107 126 141
9 100 26 37 53 63 74 82 117
140 30 43 59 73 85 94 136
210 36 50 70 85 99 110 157
280 41 57 81 97 113 126 178
12 100 24 33 47 58 67 75 108
140 29 38 54 66 77 87 125
210 33 46 65 80 92 103 148
280 37 54 76 93 106 119 170
15 100 22 31 44 54 62 68 94 155 217
140 25 36 50 62 72 80 112 178 251
210 30 42 60 75 86 94 133 212 301
280 35 48 70 87 100 108 153 247 350
24 100 17 25 36 45 52 58 81 128 180
140 21 30 42 52 60 67 94 151 208
210 25 36 51 63 72 81 115 178 252
280 29 42 60 74 85 95 136 206 296
30 100 17 23 33 40 47 52 73 116 165
140 20 27 38 47 54 61 86 136 193
210 24 32 46 56 65 73 105 162 230
280 28 37 53 66 76 85 123 187 268