Page 199 - Mechanical Engineers' Handbook (Volume 2)
P. 199
188 Temperature and Flow Transducers
63. H. A. Tasman and J. Richter, ‘‘Unconventional Methods of Temperature Measurement,’’ High Tem-
peratures—High Pressure 11, 87–101 (1974).
64. A. Benjaminson and F. Rowland, Temperature, Its Measurement and Control in Science and Industry,
Vol. 4, Instrument Society of America, Pittsburgh, PA, 1972, p. 701.
65. J. F. W. Bell, A. A. Fathamani, and T. N. Seth, 1975, cited in Von der Hardt et al., vol. 2, 1975,
pp. 649–680.
66. The Temperature Measurement Handbook and Encyclopedia, Omega Engineering, Stamford, CT,
1985, p. Q4.
67. R. J. Moffat, ‘‘Introduction to Flow Rate Measurement,’’ in Experimental Methods in the Thermo-
sciences, Mechanical Engineering Department, Stanford University, Stanford, CA, 1978.
68. H. S. Bean, Fluid Meters—Their Theory and Application, 6th ed., (American Society of Mechanical
Engineers, New York, 1971).
69. R. P. Benedict, Fundamentals of Temperature, Pressure, and Flow Measurement, 2nd ed., Wiley,
New York, 1977.
70. Ultrasonic Doppler and time-of-flight flowmeters, www.enginering toolbox.com
71. J. Flood, ‘‘Ultrasonic Flowmeter Basics,’’ Sensors Magazine, October 1997.
72. G. Yamanaka, H. Kikura, and M. Aritomi, ‘‘Study on Velocity Profile Measurement Using Ultra-
sound Time-Domain Correlation Method,’’ ASME HTD 369(3), 259–264 (2001).
73. L. Lynnworth, ‘‘Clamp-On Flowmeters for Fluids,’’ Sensors, August 2001.
74. J. Yoder, ‘‘Flowmeters and Their Apps: An Overview,’’ Sensor Technology and Design, October
2003.
75. Omega.com, technical reference section: ultrasonic flowmeters.
76. http:/ /www.efunda.com/DesignStandards/sensors/flowmeters/flowmeter ustt.cfm.
77. C. Ruppel and F. Peters, ‘‘Effects of Upstream Installations on the Reading of an Ultrasonic Flow-
meter,’’ Flow Measurement and Instrumentation 15(3), 167–177 (June 2004).
78. P. I. Moore, G. J. Brown, and B. P. Stimson, ‘‘Ultrasonic Transit-Time Flowmeters Modeled with
Theoretical Velocity Profiles: Methodology,’’ Measurement Science and Technology, 11, pp. 1802–
1811 (2000).
79. T. T. Yeh, P. I. Espina, and S. A. Osella, ‘‘An Intelligent Ultrasonic Flow Meter for Improved Flow
Measurement and Flow Calibration Facility,’’ in Conference Record—IEEE Instrumentation and
Measurement Technology Conference, Vol. 3, 2001, pp. 1741–1746.
80. M. Willatzen, ‘‘Ultrasonic Flowmeters: Temperature Gradients and Transducer Geometry Effects,’’
Ultrasonics 41, 105–114 (2003).
81. J. Berrebi, P.-E. Martinsson, M. Willatzen, and J. Delsing, ‘‘Ultrasonic Flow Metering Errors Due
to Pulsating Flow,’’ Flow Measurement and Instrumentation 15(3), 179–185 (June 2004).
82. C. Carlander, and J. Delsing, ‘‘Installation Effects on an Ultrasonic Flow Meter with Implications
for Self Diagnosis,’’ Flow Measurement and Instrumentation 11(2), 109–122 (2000).
83. M. J. Vermeulen, G. De Boer, and J. Bowen, ‘‘A Model for Estimation of the Ultrasonic Noise Level
Emitted by Pressure Regulating Valves and Its Influence on Ultrasonic Flowmeters,’’ in Proceedings
of the Annual ACM-SIAM Symposium on Discrete Algorithms, 2001, pp. 435–444.
84. I. Fyrippi, I. Owen, and M. P. Escudier, ‘‘Flowmetering of Non-Newtonian Liquids,’’ Flow Mea-
surement and Instrumentation 15(3), 131–138 (June 2004).
85. F. J. Weber, H. Johari, and W. W. Durgin, ‘‘Ultrasonic Beam Propagation in Turbulent Flow,’’ in
Proceedings of the ASME Fluids Engineering Division Summer Meeting, Vol. 1, 2003, pp. 85–91.
86. J. Lansing, ‘‘Dirty vs Clean Ultrasonic Gas Flow Meter Performance,’’ in Proceedings of the Annual
ACM-SIAM Symposium on Discrete Algorithms, 2002, pp. 989–999.