Page 168 - Modern Control of DC-Based Power Systems
P. 168

132                                 Modern Control of DC-Based Power Systems


          5.2.3 Simulation Results
          5.2.3.1 Cascaded System
          A cascaded converter setup has been modeled in Matlab-SIMULINK
          with the parameters described in Table 6.1. In the simulation, a step vari-
          ation of the CPL load has been performed. The variation of the bus volt-
          age during the step change of the CPL load is described in Fig. 5.9.At
          t 5 0.25 s the load step of 7.5 MW was performed, demonstrating that
          the Synergetic control stabilizes the system towards the reference point
          V ref 5 1: The dynamic of the inductor current is described in Fig. 5.10.


          5.2.3.2 Shipboard Power System
          A Shipboard Power System has been modeled in Matlab\SIMULINK,
          based on the parameters in Table 6.2. The load steps of 22.5 MW have
          been performed at t 5 0.25 s. The coefficients of the droop controllers
          were chosen to obtain an even current sharing among the converters. All
          converters equally share the total load power between them.
             The effect of the increasing and decreasing of the CPL load on the
          load voltage is described in Fig. 5.11, demonstrating that the voltage
          remains stable and reaches the voltage set-points that are gradually modi-
          fied by the action of the droop control. In Fig. 5.12 one can observe the
          transient for the current.



























          Figure 5.9 Voltage synergetic cascaded   Ideal CPL   Step 10.3 - 17.8 MW.