Page 204 - Packed bed columns for absorption, desorption, rectification and direct heat transfer
P. 204

194


                                                                          1/6
                                 jr.                                                         (54)
                                       1/6
                                      a                             8 Pi)    \PG


                             is the liquid superficial velocity at the loading point.
                                  The function y/ s is given by the equation:


                                        f    f   \0.4  -2n,
                                 g           (ML)                                            (55)
                                C 2          UJ




                                                                                             (56)






                               ^L l£e_£0.4      n s=-0.326                   from Table 6.
                                V

                                                                                  0,1588
                           Fo r ±L Bt           n s= -ft723    C s2 = 0.695CJ&-




                           C ti is an experimental constant presented in Table 6, depending on the packing
                           type and dimension. L L and V are the liquid, respectively the gas, flow rate in
                           kg/h.
                                  For determination of the flooding point Billet and Schultes [316]
                           proposed the equations:



                           Wr  =                                                             (57)
                                              ,1/2
                                                        a \p G


                           H tF is the total holdup of the liquid phase at the flooding point The function
                               is calculated by the equation
   199   200   201   202   203   204   205   206   207   208   209