Page 492 - Pipelines and Risers
P. 492

Pipe-in-Pipe and Bundle Systems                                       459


                                   r----l
                                         DESIQN
                                               BASIS

                                           SIZE (ID)

                                  4 ESTABLIHED FLOWLINE   I
                                          SIZE (WT)

                             NOT OK
                     b                CHECK HOOP STRESS


                                     MATERIAL 8 THICKNESS

                                   -1
                                      INSULATION SYSTEM

                                      ESTABLISH MINIMUM
                                       CARRIER  SIZE (ID)

                                     DETERMINE BUOYANCY
                                        REQUIREMENTS

                                       SELECT SUITABLE
                                        CARRIER SIZE
                                          (OD
                                             X
                                               WT)
                                    DETERMINE SUBMERQED
                                      INSTALLED WEIGHT









                                                          NOT OK
                                          STRESSES


                                        BUNDLE
                                   r--j--i OPTION
        Figure 24.2 Design flow diagram for bundle system.
        The submerged weight of the bundle is compared with the minimum submerged weight of the
        bundle required to  satisfy Morison’s classical two dimensional theory.  The cyclic  varying
        horizontal velocity in the water particles introduced by the design wave are superimposed on
   487   488   489   490   491   492   493   494   495   496   497