Page 270 - Practical Machinery Management for Process Plants Major Process Equipment Maintenance and Repair
P. 270

252    Major Process Equipment Maintenance and Repair



                                                   H. S. Shaft
                                                                   Towards Gear






                                                                           I-
                                                                           O
                                     Center of Journal a  y                9
                                     Running Position
                                                            -              I
                                                                           5
                                   Center of Journal                       .-
                                   at Cold Position                        I

                                        Figure 6-26.  Example of thermal movement.





                                                                         Dowel Pins





                                                                          Gear Unit
                                                           0
                                                           8


                                         Figure 6-27. Ideal cold alignment example.











                          In the example illustrated  in Figure 6-26, the thermal  and mechanical
                        movements have been determined as .007 in. vertical and .002 in. horizontal
                        toward the gear. Using these values, the cold indicator reading should be as
                        shown in Figure 6-27. In this example the assumption is made that the pump
                        remains in the ambient condition. If this supposition is not true, the indicator
                        readings must be corrected for the pump movement.
   265   266   267   268   269   270   271   272   273   274   275