Page 393 - Practical Machinery Management for Process Plants Major Process Equipment Maintenance and Repair
P. 393

EXHAUST END
                                                                                                                 b
                                                                                     Ila  INCH (3 mm)  DIAMETER PLASTIC.   a
                                                                                     STRING COMPOUND ON VERTICAL1   8
                                                                                     PACKING CASE FLANGES.
                                                                                                                 8



                                                                                                        ING
                                                               TIC STRING COMPOUND IN A  LAYER
                                                               OF  PASTE  COMPOUND  APPROXI-
                                                               MATELY 1/2  INCH (13 mm) WIDE




                              USE  ONLY  PASTE  COMPOUN
                              ON  HORIZONTAL  PACKING  CAS
                              FLANGES.




                                               Figure 8-8. Horizontal joining detail on a typical general purpose turbine.