Page 450 - Practical Machinery Management for Process Plants Major Process Equipment Maintenance and Repair
P. 450

428   Major Process Equipment Maintenance and Repair

                     Junction Box

                       Junction boxes should always remain closed except during the actual
                     installation period. In no case should it be allowed to stand open over-
                     night or for extended periods. This will protect the electrical circuitry
                     from dirt, rain, moisture and other sources of potential electrical abuse.

                     Electrical Conduit Seals

                       If the process gas is combustible, electrical conduit seals are to be
                     poured only after verifying that all electrical components and circuitry
                     are functioning correctly.

                     Control Panel

                       Install and check instrument air lines and electrical sensor lines as indi-
                     cated on control panel junction box and system schematic drawings fur-
                     nished by vendor. Before applying power, check that there are no shorts
                     to ground.



                                            Operating Instructions
                     Precautionary lnstructlons

                       If, after installation, it is believed there is significant possibility of in-
                     jurious foreign matter having entered the unit, it must be disassembled
                     and all parts cleaned and reassembled before initial startup. Verify that
                     the cold section of the expander is free of oil or grease. Assembly and
                     disassembly instructions must be carefully observed.
                       This may be a good time to have the manufacturer’s service person in-
                     struct your operating personnel in the assembly and disassembly of the
                     unit.
                       It should be noted that there is a danger of overspeed until the compres-
                     sor suction reaches design pressure. The expander could reach full speed
                     with less than full  expander power until the compressor suction design
                     pressure has been established.


                     Procedure for Filling Reservoir

                       Refer to the system schematic drawing furnished by the expander man-
                     ufacturer.
                       Fill the lube oil reservoir with lubricant in accordance with specifica-
                     tions given by the manufacturer.
   445   446   447   448   449   450   451   452   453   454   455