Page 288 - Principles of Applied Reservoir Simulation 2E
P. 288

Part IV:  WINB4D  User's  Manual  273


       3.    Heading    Up to 80  characters.
             Omit this record ifNWELLN  = 0.


       4.    WELLID
             Omit this record  ifNWELLN  =  0.
             WELLID     Well name with up to five characters.


       5     IDWELL, KONECT
             Omit this record ifNWELLN  = 0.
             IDWELL     Well identification number. Each well should have a unique
                        IDWELL   number.  If  two  or  more  wells  have  the  same
                        IDWELL number, the characteristics of the last well entered
                        will be used.
             KONECT     Total number of gridblocks connected to well IDWELL.


       6.    I, J,  K, PID, PWF
             Omit this record ifNWELLN  =  0.
             I          x coordinate of gridblock containing well.
             J          y  coordinate of gridblock  containing well.
             K          z coordinate of gridblock containing  well.
             PID        Layer flow index for  gridblock.
             PWF        Flowing bottomhole pressure for block (psia). This value is
                        used only if KIP is negative for this well.
                        NOTE: KONECT records must be read. PID for a vertical
                        well can be estimated as
                                               Kh
                            PID  =  0.00708
                                           In



                        where
                                          2      2 l/2
                            r 0  -  0.14 (DX  +  DY )

                        and
   283   284   285   286   287   288   289   290   291   292   293