Part IV: WINB4D User's Manual 27?
ID WELL number, the characteristics of the last well entered
will be used.
KONECT Total number of gridblocks connected to well IDWELL
12. I, J, K, PID, PWF
Omit this record if NWELLO = 0.
I x coordinate of gridblock containing well.
J y coordinate of gridblock containing well.
K z coordinate of gridblock containing well.
PID Layer flow index for gridblock.
PWF Flowing bottomhole pressure for block (psia). This value is
used only if KIP is negative for this well.
NOTE: KONECT records must be read.
13 KIP, QO, QW, QG, QT
Omit this record if NWELLO = 0.
KIP Code for specifying well operating characteristics. See
record 6 for a description of the KIP options.
14. ALIT, BLIT
Omit this record if NWELLO = 0 or KIP * -4.
ALIT "a" coefficient of LIT gas well analysis.
BLIT "b" coefficient of LIT gas well analysis.
NOTE: Records 10 through 14 should be repeated NWELLO times.