CATALYST  CHARACTERIZATION                                       175

           those distinguishing features  important for proper use.  The correct reactor
           should be selected for the task at hand. It is not sufficient to use an apparatus
           merely because it is available. Will it yield necessary data without complicat-
           ing the interpretation? Carefully assess the requirements of the experiment
           and  keep  the  reactor as  simple as  possible.  Avoid  the temptation to  build
           versatility,  for  experience  has  shown  that  the  more  functions  a  piece  of
           equipment performs, the greater the probability of malfunction. Limitations
           must be recognized,  however, and expectations clearly defined.
               Most  experimental  reactors  have  one  common  feature-small  size.
           Catalyst  beds  are  small,  usually  less  than  1 g,  perhaps  mixed  with  inert
           material to give reasonable volumes (1-2 cm'). This is  a distinct advantage.
           Catalyst costs are low because only small amounts need be prepared.  Heat
           transfer and control difficulties  are  minimal and temperature is  accurately
           measured. Auxiliary equipment such as tubing, valves, pumps, and gauges,
           are  low  cost  and  easily  fabricated.  Reagent  supplies  are  reasonable  and
           available from easy storage. Space is conserved. Microanalytical equipment
           exists  for  most applications.  There are,  however, compensating disadvan-
           tages. With small9atalyst beds, there are reproducibility problems, especially
           with  laboratory preparations.  Small  beds  are  much  more  sensitive  to  low
           concentrations of poisons, so that reactants must be thoroughly cleaned to
           ultrapure  levels.  The  catalyst  is  often  used  as  a  powder,  since  reactor
           diameters are low. Although pore diffusion problems are minimized, press-
           ure  drop  difficulties  arise.  With  low  flow  rates,  the  particle  Reynold s
           number, Rep, is small and the flow regime ill defined. Values of Rep  greater
           than 25-50 are necessary for turbulent flow;  below that it is  laminar. Many
           laboratory  reactors  have  values  less  than  1-10,  where  external  diffusion
           correlations  are  uncertain.  However,  if  these  objections  are  overcome,
           laboratory reactors offer the most rapid, least expensive, and simplest way
           to accumulate rate data.
               There are four major types (1) tubular, (2) gradientIess, (3)  batch, and
           (4)  pulse.


           7.5.2.1.  Tubular Reactors
               A typical tubular reactor system is shown in Fig. 7.31. The reactor itself
           is  made  of glass,  quartz,  or stainless  steel,  depending on the temperature
           and pressure. The diameter and length should not be less than that required
           to give tube to particle diameter ratios of 5-1 0 and length to particle diameter
           ratios of 50-100. Auxiliary flow and measuring equipment is  shown in Fig.
           7.32.
               The reactor is  operated either in  an  integral  or differential  mode.  As
           an integral  reactor, initial concentrations of reactants are adjusted and the