Page 229 - Reciprocating Compressors Operation Maintenance
P. 229
214 Reciprocating Compressors: Operation and Maintenance
-Oft- GATE MklVE
-CX}- OL06E \*IVE
-tJH WEUMON
HOI- SKWT ROW
V DRAIN
—Forced Coolant System.
VENT AND FILL
CONNECTIQN-
TJ " __ _
-SMALL EXPANSION
CHAMBER
NOTES
-C*3- GATE VftlVE
-C#J- SATE VMVE _Q JQ_ f3ugK
"**" niT » ' H|H P.PEUWON
Hd- SGHT R.OW
-|O|- SBHT FUOW
V DRAM
'./ DRAW
—Thermal Syphon Syilem.
—Static System.
FIGURE 3-64. Piping schematics for different types of cooling systems,
1. The cooling water should be passed through the intercooler first and
then this warmer water to the cylinder in a series arrangement.
2. Quantity of water should be regulated so that outlet temperature is
not more than 15°F above the inlet water temperature.
= t 0 -tj=15°F
Cooling system flows (Rule of thumb)