Page 211 - Root Cause Failure Analysis
P. 211

Inverters     199

                                 0.9





                               0.875
                       Per unit
                      &ties

                                0.85




                               0.825
                                    0      1       2       3      4      5
                                                  Time  (see)
                  Figure  165 Impact load-response comparison for V/Hz and  sensorless, jlm-vector-type
                  inverters.


                  during  rapid  acceleration, are  important  performance  measurements.  Figure 16-6
                  shows the response characteristics of  a flux-vector-type inverter, which can supply
                  three times full torque in less than 1 sec. The ability to maintain full torque, as well as
                  the ramp or acceleration rate of the motor, is essential in critical applications.




                                    3.0
                                    25 -

                                    20 -

                           Per unit  15 -
                              of
                          Quantities
                                    10 -

                                    0.5 -

                                                                   0 ShafiTorque
                                     0.                            0 Motor Sped

                                    45
                                       0       1       2       3       4      5
                                                      Time (sec)
                  Figure I66 Flux-vector inverter response charaeteristks.