Fiber Optics in Sensors and Contr ol Systems
                     3.17  Dual Laser Test Sets                                        175
                          The Photodyne 2260XF and 2260XFA are switchable dual laser test
                          sets, with a transmit and receive section in one unit. They measure
                          and display loss in fiber links at both 1300 and 1550 nm simultane-
                          ously in one pass. They are designed for use in installing, maintaining,
                          and troubleshooting single-mode wavelength-division multiplexed
                          (WDM) fiber-optic links operating at 1300- and 1550-nm wavelengths.
                          They may also be used for conventional links operating at either 1300
                          or 1550 nm.
                             The essential differences between the two models are that the XF
                          version (Fig. 3.55) has a full complement of measurement units, log
                          and linear (dBm, dB, mW, µW, nW), whereas the XFA version has
                          log units only (dBm, dB). In the XF version, laser power output is












































                          FIGURE 3.55  Photodyne 2260XF switchable dual laser test set. (Courtesy 3M
                          Corporation)