Page 142 - Serious Incident Prevention How to Achieve and Sustain Accident-Free Operations in Your Plant or Company
P. 142

CH11pp111-125  4/10/02  12:51 PM  Page 119

                                          Measurement and Feedback     119


                      Responsibility clarified and  Will expedite completion





                   Comments  lights inspected






                   Date Completed  2-1-xx  2-5  3-24












            TABLE 11-3  Critical Work Not Completed on Schedule—Status of Follow-Up Action  Projected Completion  2-1-xx  2-7  3-24  4-7





                      Confusion over responsibility




                   Cause     Instructions unclear to maintenance personnel on location of fire door that  needs to be repaired  2 operators missed due   to vacations  Conflicting priorities










                   Item Behind Schedule  Emergency light inspections  Corrective action for  repairing fire door found  on last month’s inspection  Evacuation training  Investigative report not  yet issued on chemical   spill that occurred in   December
   137   138   139   140   141   142   143   144   145   146   147