Page 175 - Standard Handbook Petroleum Natural Gas Engineering VOLUME2
P. 175

144   Reservoir Engineering


                                   Rxo = 10, Rxo/R,  = 20, Frequency = 20 kHz
                           70
                           50



                           20
                         2
                         n
                        E-  10
                        'b
                        cr"
                            5



                            2

                            1
                                 1                      2             3         4
                                                   RIMP~RIDPH

                   Figure 5-79g.  Invasion correction chart for the phasor dual induction-Rxo log
                   combination for  Rxo = 10, Rxo/Rm = 20 [199].



                          400
                          200

                          100
                           50
                        E
                        c2
                           20
                       io
                        cr"
                           10






                                                     2           3        4
                                                    RIMPH~DPH


                    Figure 5-79h.  Invasion correction chart for the phasor dual induction-Rxo log
                    combination for  Rxo = 50,  Rxo/Rm = 100 [199].
   170   171   172   173   174   175   176   177   178   179   180