                                                 DESIGN OF BUILDING MEMBERS


                   6.18  CHAPTER SIX

                               where Q n = nominal strength of one shear connector, kips
                                    N s = number of shear studs between maximum positive moment and zero moment on each
                                        side of the maximum positive moment
                                 The nominal strength of a shear stud connector embedded in a solid concrete slab may be com-
                               puted from

                                                        Q = 05 A sc  f E ′ c c  ≤  R R A F u       (6.28)
                                                             .
                                                                          p sc
                                                                        g
                                                         n
                               where A sc = cross-sectional area of stud, in 2
                                     f c ′= specified compressive strength of concrete, ksi
                                    E c = modulus of elasticity of the concrete, ksi
                                          .
                                       = w 15  f ′ c
                                     w = unit weight of the concrete, lb/ft 3
                                    F u = specified minimum tensile strength of a stud, ksi
                               R g and R p are strength reduction factors, Art. 5.8.6.
                                 For a beam with nonsymmetrical loading, the distances between the maximum positive moment and
                               point of zero moment (inflection point) on either side of the point of maximum moment will not be
                               equal. Or if one end of a beam has negative moment, then the inflection point will not be at that end.







































                                           FIGURE 6.6 Seven locations of the plastic neutral axis used for deter-
                                           mining the strength of a composite beam. (a) For cases 6 and 7, the PNA
                                           lies in the web. (b) For cases 1 through 5, the PNA lies in the steel flange.


                           Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)