Page 142 - Structural Steel Designers Handbook AISC, AASHTO, AISI, ASTM, and ASCE-07 Design Standards
P. 142

Brockenbrough_Ch03.qxd  9/29/05  5:05 PM  Page 3.74



                                                        CONNECTIONS


                   3.74  CHAPTER THREE

                                 Bearing on outer plate: φr p = 0.75 × 2.4 × 0.875 × 0.50 × 58 = 45.7 kips
                                 Bearing on inner plate: φr p = 0.75 × 2.4 × 0.875 × 0.75 × 58 = 68.5 kips
                                 Tear-out on W14 × 99 flange: L c = 1.75 − 0.50 × 0.9375 = 1.281 in

                                                  φr to = 0.75 × 1.2 × 1.281 × 0.710 × 65 = 53.2 kips

                                 Tear-out on outer plate: L c = 1.5 − 0.5 × 0.9375 = 1.031 in
                                                  φr to = 0.75 × 1.2 × 1.031 × 0.50 × 58 = 26.9 kips

                                 Tear-out on inner plate: L c = 1.031 in
                                                  φr to = 0.75 × 1.2 × 1.031 × 0.75 × 58 = 40.4 kips

                                 Tear-out between bolts will not control in this case, since 3 − 0.9375 = 2.0625 > 1.281 or 1.031 in.
                               From the above, the shear/bearing/tear-out strength of the flange connection is

                                       φR vpt = 2 × 54.2 + 2 × 26.9 + 2 × 27.1 + 2 × 54.2 = 325 kips > 311 kips  OK
                               In the expression for φR vpt , the first term is for the two bolts in the center, which are controlled by
                               shear; the second and third terms are for the outer two bolts controlled by outer-plate edge distance
                               and bolt shear; and the fourth term is for the two inner bolts, again controlled by bolt shear.
                                 This completes the calculation for the flange portion of the splice. The bolts, outer plate, and
                               inner plates, as chosen above, are OK.
                                 WEB SPLICE DESIGN
                                 Member Limit States. The calculations for the web connection involve the same limit states as the
                               flange connection, except for tension rupture of the chord net section, which involves flanges and web.
                                 Bolt pattern must be established to check the web. The minimum number of bolts in double
                               shear required is (178/2)/27.1 = 3.28. Try four bolts.
                                 Bearing/tear-out will be checked after the web splice plates are designed.
                                 Block shear rupture will be checked as follows. As a first trial, assume the bolts have a 3-in
                               pitch longitudinally.

                                            A nv = (4.75 − 1.5 × 1) × 0.440 × 2 = 2.86 in 2
                                            A nt = (3 − 1 × 1) × 0.440 = 0.88 in 2
                                            A gv = 4.75 × 0.440 × 2 = 4.18 in 2
                                            A gt = 3 × 0.440 = 1.32 in 2
                                          F u A nt = 65 × 0.88 = 57.2 kips
                                        0.6F u A nv = 0.60 × 65 × 2.86 = 112 kips
                                        0.6F y A gy = 0.60 × 50 × 4.18 = 125 kips
                                            U bs = 1.0
                                           φR bs = 0.75[57.2 + min(115, 125)] = 127 kips < 178 kips  No good

                               Since the block shear limit state fails, the bolts can be spaced out to increase the capacity. Increase
                               the bolt pitch, from the 3 in assumed above to 6 in, and repeat the calculations.

                                              A nv = (7.75 − 1.5 × 1) × 0.440 × 2 = 5.50 in 2
                                              A nt = 0.88 in 2




                           Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                      Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                                       Any use is subject to the Terms of Use as given at the website.
   137   138   139   140   141   142   143   144   145   146   147