Brockenbrough_Ch03.qxd  9/29/05  5:05 PM  Page 3.81



                                                           CONNECTIONS


                                                                                          CONNECTIONS  3.81





















                                                FIGURE 3.46  Equilibrium of doubler plate with weak-axis shear load.
                                                (Source: A. R. Tamboli, Handbook of Structural Steel Connection Design and
                                                Details, McGraw-Hill, 1999, with permission.)



                                  of carrying V or R alone, they are capable of carrying their difference. The same argument applies to
                                  the top and bottom edges of the doubler. Also, the same argument holds if the moment and/or weak-
                                  axis shear reverse(s).

                                  Associated Shear Connections: Beam 1.  The specified shear for the web connection is R =
                                  163 kips, which is the shear capacity of the W21 × 62 (A36) beam. The connection is a shear plate
                                  with two erection holes for erection bolts. The shear plate is shop welded to the column flange and
                                  field welded to the beam web. The limit states are shear yielding on the plate gross section, weld
                                  strength, and beam web strength.
                                    Plate Gross Shear.  Try a plate  / 2 × 5 × 18 in.
                                                            1
                                               φR gv = 0.5 × 18 × 0.9 × 0.6 × 36 = 175 kips > 163 kips  OK

                                  Plate net shear need not be checked here, because it is not a valid limit state.
                                                                                         1
                                    Weld to Column Flange.  This weld sees shear only. Thus, weld size in  / 16ths is

                                                             D =    163    = 325.
                                                                2 ×18  ×1 392.

                                       1
                                  Use a  / 4-in fillet weld.
                                    Weld to Beam Web. This weld sees the shear plus a small couple. Using AISC Manual Table 8-9,
                                  l = 18, kl = 4.25, k = 0.24, x = 0.04, xl = 0.72, al = 4.28, a = 0.24, c = 2.70, and

                                                              D =   163   = 447.
                                                                 075 × 270.
                                                                  .
                                       5
                                  Use a  / 16-in fillet weld.
                                                        5
                                    Beam Web.  To support a  / 16-in fillet weld on both sides of a plate, AISC Manual Table 10.2
                                                                  5
                                  shows that a 0.476-in web is required. For a  / 16-in fillet on one side, a 0.238-in web is required. Since
                                  the W21 × 62 web is 0.400 in thick, it is OK.

                              Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                         Copyright © 2004 The McGraw-Hill Companies. All rights reserved.