Page 372 - The Engineering Guide to LEED-New Construction Sustainable Construction for Engineers
P. 372
A S y s t e m a t i c V i e w o f G r e e n a n d M i n i m u m P r o g r a m Re q u i r e m e n t s 333
Prerequisite or Credit Referenced Standards/Codes, etc.
IEQc4.3: Low-Emitting Materials: Flooring • Carpet Systems:
Systems CRI’s Green Label Plus program for carpet
CRI’s Green Label program for cushion
See IEQc4.1 for adhesives
• Hard Flooring Systems:
FloorScore certified for flooring
See IEQc4.2 for finishes
See IEQc4.1 for adhesives/grout
Or
• All flooring
CA Dept. of Health Services Std. Practice
for the Testing of Volatile Organic Emissions
form Various Sources using Small-Scale
Environmental Chambers, including 2004
addenda
IEQc4.4: Low-Emitting Materials: Composite None
Wood and Agrifiber
IEQc5: Indoor Chemical and Pollutant ASHRAE 52.2-1999 for MERV ratings
Source Control
IEQc6.1: Controllability of Systems: Lighting None
IEQc6.2: Controllability of Systems: Thermal • ASHRAE Standard 55-2004, w/errata:
Comfort Thermal Environmental Conditions for
Human Occupancy
• Balance with ASHRAE Standard 62.1-2007
for Acceptable Indoor Air Quality
IEQc7.1: Thermal Comfort: Design ASHRAE Standard 55-2004, w/errata:
Thermal Environmental Conditions for
Human Occupancy, Section 6.1.1
IEQc7.2: Thermal Comfort: Verification ASHRAE Standard 55-2004, w/errata:
Thermal Environmental Conditions for
Human Occupancy
IEQc8.1: Daylighting and Views: Daylight ASTM D1003-07e1: Std. Test Method for Haze
and Luminous Transmittance of Transparent
Plastics
EQc8.2: Daylighting and Views: Views None (EP: Heschong Mahone Group Study:
Windows and Offices)
IDc1: Innovation in Design None or as listed previously for applicable
EP point subcategories
IDc2: LEED Accredited Professional Green Building Certification Institute (GBCI)
accreditation
RP: Regional Priorities None or as listed previously for applicable RP
subcategories
TABLE 8.2.1 (Continued)