Page 153 - Valve Selection Handbook
P. 153

140                  Valve  Selection Handbook
















                                                             Figure  3-99.
                                                             Inherent and  Installed
                                                             Flow Characteristics
                                                             of  Weir-Type
                                                             Diaphragm Valves.
                                                             (Courtesy of
                                                             Sounders  Valve
                                                             Company limited.)


            Standards  Pertaining to Diaphragm Valves

              Appendix C provides  a list of U.S.,  British  and ISO standards pertain-
            ing to diaphragm  valves.
            Applications

              Duty for weir-type and straight-through diaphragm valves:
                Stopping and starting flow
                Controlling flow
              Service for weir-type diaphragm  valves:
                Gases,  may carry  solids
                Liquids, may carry  solids
                Viscous  fluids
                Leak-proof  handling of hazardous  fluids
                Sanitary handling of Pharmaceuticals  and  foodstuffs
                Vacuum
              Service for straight-through diaphragm  valves:
                Gases,  may carry  solids
                Liquids,  may carry solids
                Viscous fluids
                Sludges
                Slurries,  may carry  abrasives
                Dry media
                Vacuum (consult manufacturer)