           Figure 2-1. Proposed Zero Gas Leakage Criterion. (Courtesy of Jet Propulsion
           Laboratory,  California Institute of  Technology.  Reproduced  from  JPL Technical  Report
           No. 32-926.)




                          2           4
           down  to  1  X  10"  or  1  X  10"  sees  (standard cubic  centimeters  per  sec-
                                                  3
           ond), depending on the skill of the operator.
             Lower  leakage  rates  in  the  atom  class  may  be  detected  by  using  a
           search gas in conjunction with a search-gas  detector.
             Specifications  for  proving  leakage  tightness  may  be  found  in  valve
           standards  or in the  separate  standards  listed  in Appendix  C. A description
           of leakage testing methods for the atom class may be found  in BS  3636.