Page 258 - Well Control for Completions and Interventions
P. 258

252                                Well Control for Completions and Interventions


          7.3.8 Reverse circulation: worked example 1. Plugged
          vertical well
          In this example, the well is vertical and equipped with a sliding sleeve a
          short distance above the packer. The sleeve will be opened to allow circu-
          lation. A plug has been installed in a seating nipple below the circulation
          ports of the sliding sleeve (Fig. 7.1).
             Planning requirements:
          1. Calculate the gradient of kill weight fluid required to overbalance well
             pressure at the SSD by 200 psi (for the purposes of this example, brine
             weight temperature and pressure corrections have been ignored).
          2. Calculate all necessary volumes.




                                        SITHP 1900 psi


                                            SICHP 0 psi






                                  Oil gradient 0.35 psi/ft.
                                  Annulus fluid gradient 0.52 psi/ft.

                                  Kill fluid gradient 0.56 psi/ft.




                                  SSD 10,300 ft.

                                  Packer 10,330 ft.

                                  Plug 10,350 ft.
                                  Top reservoir
                                  10,500 ft TVD
                                   Reservoir pressure
                                       5570 psi



          Figure 7.1 Well schematic. Worked example 1.
   253   254   255   256   257   258   259   260   261   262   263