Page 479 -
P. 479

ACTIVATED CARBON PROCESSES              14.27







                                            ~lFlushingWater
                                             Header






                                            Water Level




                             GAC Fill
                              Header









                       ~
                           "-- GAC --~



                       ~- Underdrain
                                                Underdrain
                        Header
                                                Lateral  -7








         FIGURE  14.13  Cross section through a typical,  open-top concrete, rectangular, gravity flow GAC con-
         tactor.  (Adapted from Westerhoff and Miller, 1986.)
         •  Rate  at  which  backwash  water  must  be  applied  because  this  is  a  function  of contactor
          surface  area
         •  Ability  to provide  uniform distribution  of backwash  water  over  the effective maximum
          area  of a  single unit
         •  The  ability  to  accommodate  a  reduction  in  capacity  with  one  unit  out  of  service  for
          backwash,  regeneration,  or  maintenance