Page 142 - Advanced Design Examples of Seismic Retrofit of Structures
P. 142

134   Advanced Design Examples of Seismic Retrofit of Structures















































            FIG. 3.8 Foundation plan.


            (FC) or deformation-controlled (DC). It is noteworthy that the expected mate-
            rial strength (mean value) is used for determination of the members’ capacity
            with DC action, and the lower-bound material strength (mean value minus one
            standard deviation) is used for the members’ capacity with FC action. With
            regards to the above considerations, the model of the building is prepared,
            and linear dynamic analysis by consideration of 40 natural modes of the build-
            ing is performed.



            3.3.1 Modeling and Analysis of the Building
            The three-dimensional modeling of the building is performed by using SHELL
            elements for RC shear walls and FRAME elements for columns and beams.
   137   138   139   140   141   142   143   144   145   146   147