Page 431 - Advanced Design Examples of Seismic Retrofit of Structures
P. 431

Example of a Steel Frame Building Retrofitted Chapter  5 379


                                2 STIFF PL 500x250x12(New)
                                 500
                              170  160  170
                                                              12
                                         –
                                        6ø22 (New)
                            130         HOLE ø24                 2mm  GAP
                          500  240       4 STIFF PL 250x160x12(New)  330
                     –
                      B
                                        2PL 500x330x20(New)  20  310
                            130         POS A
                                                          90  POS A
                                   2IPE 160+
                            8
                                  2PL250x10 at flange +
                                  2PL200x10 at web(New)            500
                                4 STIFF PL 250x80x12(New)    410
                                                    POS A
                                 A
                                 –                             170
                                       2IPE 160+
                                       2PL250x10 at flange +
                                       2PL200x10 at web(New)
                     2 STIFF PL 500x250x12(New)
                   2PL A 500x330x20(New)
                                           8
                       T.O.F.New=–30                95  PL–C
                                            2 PL–B    Cut from PL–B  8 24  156  24 8
                                           STIFFENER
                                           2IPE160  24
                                                            95
                        T.O.F.=–55                                    25
                                     2L60´60´6              65  PL–B
                                              –
                                     L=12 cm  BOLT ø20          t=10mm
                                   2L60´60´6                90
                                   L=25 cm
                                  PL500´400´15
                                                                 22
                                   View
                                         A
                                                     2IPE 160+
                                                     2PL250x10 at flange +
                                                     2PL200x10 at web(New)
                              4 STIFF PL 250x80x12(New)  4 STIFF PL 250x160x12(New)
                              2 STIFF PL 500x250x12(New)  8
                              2PL A 500x330x20(New)
                                                      8
                                  T.O.F.New=–30
                                                       2 PL–B
                            –
                          BOLT ø22 & 2Nut22 (New)     STIFFENER
                                  T.O.F.=–55
                                               2L60x60x6  –
                                               L=25cm  BOLT ø20
                                            PL500x400x15

                                             View  B
                                                   –
             FIG. 5.43 Details of the base plate.