05_chap_wang.qxd  05/05/2004  3:51 pm  Page 287
                    Wet and Dry Scrubbing                                                     287

























































                       Fig. 18. Venturi tower configurationswer plant’s emission stream: (a) Fixed  Throat; (b)
                     Variable-Throat top–entry plumb bob; (c)  Variable-Throat bottom-entry plumb bob; (d)
                     Variable-Throat top-entry liquid distribution disk; (e) Variable -Throat side veriable-plates or
                     blades; (f) Variable-Throat side-movable blocks; (g) Variable -Throat vertically adjusted fod
                     decks; (h) Variable-Throat vertically adjusted drum. (From US EPA.)


                    Example 28
                       The lime/limestone FGD process has been previously discussed in this chapter.  This
                       example is a discussion of various scrubber (absorption towers) designs that may be con-
                       sidered by an environmental engineer to use to treat the emissions from the FGD process.
                       The possible choices are as follows (32,66,67):