05_chap_wang.qxd 05/05/2004 3:51 pm Page 288
288 Lawrence K. Wang et al.
Fig. 19. Spray tower types: (a) open countercurrent; (b) open cross-current. (From US EPA.)
1. Venturi scrubber
2. Spray tower
3. Tray tower
4. Packed (wet) scrubber
5. A combination tower utilizing two or more of the above choices
Solution
1. First-generation Venturi scrubbers are presented in Fig. 18. Such systems typically
used a fixed-throat design for the Venturi. As such, the throat opening used to form