06_chap_wang.qxd 05/05/2004 4:10 pm Page 322
61.5 Btu/scf/20.7 vol
No. of Emission Streams Under Review 7
none
(c)
(c)
(c)
(c)
(c)
(c)
(c)
(c)
(c)
A. Emission Steam Number/Plant Identification #6/Styrene Recovery Condenser Unit
HAP Emission Stream Data Form a Plant Contact Mr. John Leake Telephone No. (999) 555-5024 Agency Contact Mr.Efrem Johnson (b) (b) (b) (b) (b) (b) (b) (b) (b) P. Organic Content (1)c Q. Heat/O2 Content (1) R. Particulate Content (3) S. Particle Mean Diam. (3) T. Drift Velocity/SO3 (3) a The data presented are for an emis
(a) condensor vent (a) process point (a) styrene (a) organic vapor (a) 13,000 ppmv (a) provided (a) insoluble in water (a) not given (a) 104 lb/lb-mole Negligible 90ºF 2,000 scfm (max) atmospheric none/none assume 90% removal absorption, condensation b The number in parentheses denote what data should be suppli
Effluent Characteristics for Emission Stream 6
Company Glaze Chemical Company Location (Street) 87 Octane Drive (City) Somewhere (State, Zip) B. HAP Emission Source C. Source Classification D. Emission Stream HAPs E. HAP Class and Form F. HAP Content (1,2,3) b G. HAP Vapor Pressure (1,2) H. HAP Solubility (1,2) I. HAP Adsorptive Prop. (1,2) J. HAP Molecular Weight (1,2) K. Moisture Conten
Table 7 L. Temperature (1,2,3) M. Flow Rate (1,2,3) N. Pressure (1,2)
322