Page 506 - Air and Gas Drilling Manual
P. 506

.
                                            0 375 ft
                                      D
                                        2
                                   The total length of the lumped drill  pipe tool  joints  increment (fourth), H 4, in
                               the openhole section of the annulus is  Chapter 10: Stable Foam drilling    10-31
                                                 ,
                                                2 500
                                      H 4   15 .
                                                 30
                                      H 4   125 ft
                               The inside diameter of the openhole along this  length of  this  openhole section  of
                               the annulus is
                                      D h   0 656 ft
                                             .
                               and the outside diameter of the drill pipe tool joints along this length is

                                      D     0 552 ft
                                            .
                                        3
                                   The total length of the drill collar increment (fifth), H 5, in  the openhole section
                               of the annulus is
                                      H 5   500 ft

                               The inside diameter of the openhole along this length of the openhole section of the
                               annulus is

                                             .
                                      D h   0 656 ft
                               and the outside diameter of the drill collars along this length is
                                      d    675 inches
                                            .
                                       4
                                            d 4
                                      D 4
                                            12
                                             .
                                      D     0 563 ft
                                       4
                                   Using  the  description  of  the  annulus  geometry  given  above  each  of  the  five
                               increment changes in  cross-sectional  area  can  be  analyzed  starting  with  the  stable
                               foam flow exiting at the top of the annulus.
   501   502   503   504   505   506   507   508   509   510   511