Amphibionics 05  3/24/03  8:44 AM  Page 154
                                                       Amphibionics
                                          Calibration
                                          To calibrate the infrared sensor board, a multimeter with frequen-
                                          cy measuring capabilities like the one shown in Figure 5.46 will
                                          be used. Connect a 5-volt DC source to the circuit, as shown in
                                          Figure 5.47. Connect the positive lead of the multimeter to the
                                          point shown in Figure 5.47, and connect the common lead to the
                                          circuit ground. Set the multimeter to read frequency. Use a small
                                          screwdriver  to  adjust  potentiometer  R3,  until  a  frequency  of
                                          approximately 43 kHz is displayed. This will adjust the circuit so
                                          that  the  555  timer  is  producing  a  5-volt  square  wave  that  will
                                          modulate the infrared LEDs at a frequency that is close to where
                                          the PNA4602 sensor module will respond. The circuit frequency
                                          will be fine-tuned with a software routine later in the chapter.



                      FIGURE 5.46
                      Fluke 87 digital
                      multimeter with
                      frequency measuring
                      capabilities.