Page 103 - Applied Process Design For Chemical And Petrochemical Plants Volume III
P. 103

66131_Ludwig_CH10B  5/30/2001 4:18 PM  Page 71










                                                                    Heat Transfer                                           71















































































                     Figure 10-35C. Temperature efficiency, 2 shell passes, 4 or a multiple of 4 tube passes. (Used by permission: Standards of Tubular Exchanger
                                           th
                     Manufacturers Association, 7 Ed., Figure T—3.3B, ©1988. Tubular Exchanger Manufacturers Association, Inc. All rights reserved.)
   98   99   100   101   102   103   104   105   106   107   108