Page 224 - APPLIED PROCESS DESIGN FOR CHEMICAL AND PETROCHEMICAL PLANTS, Volume 1, 3rd Edition
P. 224
196 Applied Process Design for Chemical and Petrochemical Plants
100 50 40 30 20 15 10 876 5 4
20000
15000
v)
a
5
a
a
10000
9000
8000
7000
6000
5000
4000
3500
100 50 40 30 20 15 10 876 5 4
H = TOTAL HEAD IN FEET (FIRST STAGE)
Figure 3-49. Upper limits of specific speeds for single suction, mixed and axial flow pumps handling clear water at 85°F at sea level. (By per-
mission, Hydraulic Institute Standards for Centrifugal, Rotary, and Reciprocating Pumps, Hydraulic Institute, 13th ed., 1975 [17].)