Page 247 - APPLIED PROCESS DESIGN FOR CHEMICAL AND PETROCHEMICAL PLANTS, Volume 1, 3rd Edition
P. 247

Pumping off  Liquids                                     21 9


                                            QUINTUPLEX  SINGLE-ACTING  PUMP




             Variation Above Mean, 1.8%
             Variation Below Mean, 5.270
             Total Variation,   7.  %



                                                      72O          1440         216O          2880          360°


                                            SEXTUPLEX  SINGLE-ACTING  PUMP




            Variation Above Mean, 4.82%
            Variation Below Mean, 9.22%
            Total Variation,   14.0470




                                         00          60°       1200        18Go       240°       3090        360°
                                            TRIPLEX  SINGLE-ACTING  PUMP

            Variation Above Mean,  6.1%
            Variation Below Mean,  16.9y0
            Total Variation,    23.  %

                                        00                     1200                   240°                  360°
                                            QUAD R UP1 EX  SING LE-ACT IN G  PUMP




            Variation Above Mean,  f 1.  yo
             Variation Below Mean, 21.575,
            Total Variation,    32.5Yo


                                        00               90°               1800             270°             360°
                                           DUPLEX  DOUBLE-ACTING  PUMP




             Variation Above Mean, 24.1%
             Variation %elow Mean, 21.57,
             Total Variation,   45.670





                             Figure 3-68. Reciprocating pump discharge Blow patterns. (Courtesy the Aldrich Pump Co.)
   242   243   244   245   246   247   248   249   250   251   252