392     Centrifugal Pumps: Design and Application

        an effective way of reducing the power loss of a flat sealing face by as
        much as 30%. The hydropad design feature is shown in Figure 17-29. In
        most applications this will permit the seal to operate in a very stable con-
        dition with very low leakage to the atmosphere. Leakage rates from these























































        Figure 17-28B. Piping plans for mechanical seals from A.P. I. Standard 610,6th
        Edition, (Reproduced courtesy American Petroleum Institute.)