Vertical Pumps    117












































        Figure 9-4. Submersible well pump (courtesy BW/IP international, Inc. Pump
                                               1
        Division, manufacturer of Byron Jackson/United " Pumps).


        sure, plus the static liquid level above the first-stage impeller, less cor-
        rection for the liquid vapor pressure at the pumping temperature.
          Because the cost of a pit or intake structure is high and dependent on
        the depth of the structure, the submergence is typically kept to a mini-
        mum in line with sound design practices. As a result, the maximum pump
        speed is limited by the NPSH available and the required flow rate. Sin-
        gle-stage pumps can usually be furnished for pumping heads up to 200
        feet, but multi-stage pumps are required for higher heads. The bowl di-
        ameters of well pumps and their corresponding flow rates are restricted.
        However, wet pit pumps can be furnished in any size and therefore for