Page 432 - Construction Waterproofing Handbook
P. 432

10.34   CHAPTER TEN

















































                         FIGURE 10.35 Vertical-to-horizontal transitions must be watertight. (Courtesy of Emseal)


                         As with waterproofing systems, water leakage through roof areas is typically located
                      within 1 percent of the entire surface area, most often occurring at termination and
                      transition details.  This often occurs at equipment supports, equipment pads, plumbing
                      stacks, scuppers, drains, skylights, and lightning and electrical equipment. Detailing tran-
                      sitions properly, and providing differential movement at these areas, ensures watertight
                      transitions to roofing materials. Movement allowance for roofing details includes move-
                      ment created by vibrations from mechanical equipment. Figures 10.36 and 10.37 detail
                      transitions between multi-ply and single-ply roofing systems into deck-coating or mem-
                      brane waterproofing systems.