Page 92 - Construction Waterproofing Handbook
P. 92

BELOW-GRADE WATERPROOFING  2.55





                            MIRADRI M-800
                                  MASTIC
                           MIRADRAIN 6200
                           MIRADRI 860/861
                           MIRADRI PRIMER
                                3
                            MIN. /4" LM-800
                           FILLET OR LATEX
                          CONCRETE FILLET





































                                                                                 MIRADRI M-800
                                                                                 MASTIC

                         FIGURE 2.69 Typical sheet membrane application detailing. (Courtesy of TC MiraDRI)


                            Hot systems are extremely difficult to apply to vertical surfaces due to the weight of felts.
                         Also, roofing asphalts and coal tars are self-leveling in their molten state, which causes
                         material to flow down walls, during application. Safety concerns are multiplied during their
                         use as waterproofing, because of difficulties in working with the confined areas encountered
                         at below-grade details.