Page 459 - Corrosion Engineering Principles and Practice
P. 459

426    C h a p t e r   1 0                                                             C o r r o s i o n   i n   S o i l s   a n d   M i c r o b i o l o g i c a l l y   I n f l u e n c e d   C o r r o s i o n    427



                                             1.500"


                               316L SS
                                   or                Epoxy
                               Titanium
                                                           2.250''





                                                          2" NPT 304 SS
                                                          or PVC
                                                         Structural conductor



                                                   6-Pin sealed connector
                                                 (a)




























                                                 (b)
                      FIGURE 10.13  (a) Schematic and (b) picture of the BioGEORGE MIC detection
                      probe. (Courtesy of George Licina, Structural Integrity Associates, Inc)

                      electrode pairs [12]. The production of sulfides or concentration of
                      chlorides by microbial action has been shown to produce a nearly
                      instantaneous  change  in  the  potential  of  the  electrode  pair,  thus
                      providing an indication of specific microbial activity.
   454   455   456   457   458   459   460   461   462   463   464