Page 460 - Corrosion Engineering Principles and Practice
P. 460
426 C h a p t e r 1 0 C o r r o s i o n i n S o i l s a n d M i c r o b i o l o g i c a l l y I n f l u e n c e d C o r r o s i o n 427
2.0
Applied current, microamps 1.0 formation
1.5
Action level
Biofilm
begins
0.5
Clean baseline
0.0
6/4/2001 6/18/2001 7/2/2001 7/16/2001 7/30/2001 8/13/2001 8/13/2001 9/10/2001 9/24/2001
FIGURE 10.14 A plot of signals generated by a BioGEORGE MIC detection probe.
(Courtesy of George Licina, Structural Integrity Associates, Inc).
FIGURE 10.15 Control box of a BioGEORGE MIC detection probe. (Courtesy of
George Licina, Structural Integrity Associates, Inc)