Page 576 - Corrosion Engineering Principles and Practice
P. 576

538   C h a p t e r   1 3                              C a t h o d i c   P r o t e c t i o n    539


                  Insulated header cable to
                  power source and other
                    grounded anodes
                              Insulated connection between   Tamped earth fill
                              cable and anode pigtail wire







                                                                         1.2 M

                 Insulated pigtail
                  wire provided
                   with anode

                   Anode centered in cross          Anode: high silicon cast
                   sectional fill of tamped            iron or graphite
                    carbonaceous backfill

                 FIGURE 13.13  Typical horizontal impressed current anode installation.




                 Insulated header cable to
                  power source and other
                    grounded anodes   Insulated connection between
                                      cable and anode pigtail wire
                                                             Tamped earth









                                                Insulated pigtail wire
                                                provided with anode
                                                                     Anode length
                                                                       + 1.5 M





                                                 Anode: High silicon cast
                                                    iron or graphite
                   Well tamped carbonaceous
                    material in augered hole
                     with anode and backfill
                 FIGURE 13.14  Typical vertical impressed current anode installation.
   571   572   573   574   575   576   577   578   579   580   581