Page 273 - Design and Operation of Heat Exchangers and their Networks
P. 273

260   Design and operation of heat exchangers and their networks




                                     TAC  ($/yr)  109,768  109,536  109,938  109,535  108,072




                                     Q CU  (kW)  120  100  80  101.10  104.35



                                     Q HU  (kW)  200  180  160  181.10  184.35



                                     Q E4  (kW)  1080  1080  1080  1080  1080



                                     Q E3  (kW)  1320  1320  1320  1320  1320
                                 mixing).        698.90  712.51


                                 (isothermal  Q E2  (kW)  680  700  720



                                 Δt min  Q E1  (kW)  500  500  500  500  483.14

                                 different  (kW/K)



                                 under  _  C c,E3  13.2  13.069  12.941  13.076  13.032

                                 method  (kW/K)


                                 design  _  C h,E4  18  18  18  18  20.724

                                 pinch

                                 of    (°C)        design
                                 Results  t pinch  125  125  125  125


                                 6.5
                                 Table  Δt min  5  4  3  4.0550  Optimal
   268   269   270   271   272   273   274   275   276   277   278