Page 289 - Design of Reinforced Masonry Structures
P. 289

COLUMNS                           5.9

         For h/r ≤ 99
                                      ⎡    h  2 ⎤
                                     ]
                      φP = 080 φ P′ +  P′ 1 −
                            .
                               [
                                      ⎢
                                    s ( ) ⎥
                        n        m    ⎣  140 r ⎦

                                                  ⎡    h  2 ⎤
                            .
                          = 080 φ 0 [ .880 ′ f ( A n  − A )  + f A ] ⎢ ⎣ 1− ( ) ⎥ ⎦  (5.10)
                                               y
                                           st
                                    m
                                                st
                                                     140r
         For h/r > 99
                                   m ( )
                              .
                         φP = 080 φ P′ +  P′]  70 r  2
                                  [
                                       s
                           n
                                          h
                                                 y ( )
                                            A
                                 φ 080
                              .
                            = 080 [ .  f ′( A − A ) +  f A ]  70 r  2      (5.11)
                                             st
                                                   st
                                       m
                                          n
                                                      h
         Alternatively, Eqs. (5.10) and (5.11) can be written as a single equation given by Eq. (5.12):
                                  φ
                                   [
                                .
                                     .
                          φP = 080 080  f ′( A −  A +  f A C         (5.12)
                                                     ]
                                               )
                                                   y
                                              st
                                                       P
                                                    st
                            n
                                        m
                                           n
           In Eq. (5.12), C  is a modifier (less than 1.0), which accounts for lateral stability of the
                      P
         column. It is a function of limiting column slenderness ratio h/r:
                                h        ⎡    h  2 ⎤
         For                     ≤ 99, C = 1 −  ( ) ⎥                (5.13)
                                         ⎢
                                r     P  ⎣  140 r ⎦
                                          70
                                            r
                                h      P ( ) 2
         For                     > 99, C =                           (5.14)
                                r          h
         Use of Eqs. (5.13) and (5.14) require calculating radius of gyration r of the column cross
         section. Masonry columns are generally rectangular, so the radius of gyration for such
         columns can be expressed as
                                    r =  I  A /                      (5.15)
                                         min  n
         where A  = bt
               n
               b = actual width of column
               t = actual depth of column (b > t), the least cross-sectional dimension
                   3
             I min  = bt /12.
           With the above substitutions, Eq. (5.15) can be expressed as
                                  r =  (bt 3 /12 )  =  t            (5.16a)
                                       bt     12
         Alternatively, Eq. (5.16a) may be expressed in a simpler form as
                                     r ≈ 0.289t                     (5.16b)
         Most practical masonry columns would fall into the column height category for which
         Eq. (5.13) would apply; Eq. (5.14) would apply for unusually long columns. For example,
         for a 24 × 24 in. (actual dimensions) column,
                        r = 0.289t = 0.289(24) = 6.936 in.
                        h
                     For  = 99 and r = 6.936 in., h = (99)(6.936)/12 ≈ 57 ft
                        r
   284   285   286   287   288   289   290   291   292   293   294