5.64                       CHAPTER FIVE

           Since M /V d  ≥ 1.0, the nominal shear strength of the column is limited to
                   u v
                 u
                           V ≤ 4  A n  f ′ m
                            n
                             ≤ ( 4 369 )(  2000)
                             ≤ 66 009,  lb ≈ 66 kips .  > 48.556 kips
           Therefore,         V = 48.56 kips (the smaller value governs)
                               n
                             f V  = 0.8 (48.56) = 38.85 kips
                              v n

         5.11 MASONRY PIERS


         Piers are essentially columns that might have wall segments-like appearance. It is quite common
         for some masonry walls in a building to have openings; the wall segments between the openings
         are commonly referred to as piers. However, these wall segments are not isolated, and as such not
         considered piers under the MSJC-08 provisions. For design purposes, these structural elements
         are considered wall segments, which may be subjected to in-plane or out-of-plane loads.
           For design purposes, a pier may be treated as a column under combined axial and flex-
         ural loads, discussed earlier in this chapter. According to MSJC-08 Section 3.3.4.3 [5.1],
         a pier is an isolated vertical member which meets the following prescribed dimensional
         limitations (Fig. 5.19):








                                                             h < 5l or
                                                              >15t
                                                              <30t
              Min 6"  t
              Max 16"

                                  I > 3t
                                  < 6t
                              (a) Plan – section    (b) Elevation – section
              FIGURE 5.19  Definition of a pier. (a) Plan – section and (b) Elevation – section.
         1. Horizontal dimension (b) measured at right angles to its thickness (t) is between 3 and
           6 times its thickness (3t ≤ b ≤ 6t).
         2. The nominal thickness (t) of the pier is not to exceed 16 in.
         3. Clear height (h) is less than five times its length (h < 5b). However, if the factored axial
           load at the location of maximum moment is less than 0.05  ′ f  A , the length of the pier
                                                      m  g
           can be equal to its thickness.
         4. The distance between lateral supports of a pier is not to exceed 25 times its nominal
           thickness (t).