218 3. GENERAL DESIGN OF A SOLAR THERMAL POWER PLANT
FIGURE 3.64 Parabolic trough collector loop.
Center-to-center distance between collector units in the thermal
collection loop is normally three times of the width of aperture of
parabolic trough concentrator. For example, in case of the width of
aperture of concentrator being 5.7 m, the center-to-center distance
shall be about 17e20 m.
Layout of power tower concentration field will be explained in
details in Section 4.2. Normally, there are two ways, namely the
northward concentration field and encircled concentration field.
Fig. 3.65 displays an example of the northward concentration field.
3. Steam generating area. A steam generating area includes such
major equipment as feed water preheater, evaporator,
superheater, and reheater. In case of the heat-transfer medium
FIGURE 3.65 Concentration field of PS10 power tower plant in Spain [32].