230              4. DESIGN OF THE CONCENTRATION SYSTEM



























                        FIGURE 4.3  Azimuth-elevation tracking heliostat [20].



























              FIGURE 4.4  Operational principle of the spinning-elevation tracking heliostat [33].

               In polar two-axis tracking, the fixed axis is parallel to the Earth’s axis.
            When regularly tracking the movement of the Sun, the tracker revolves
            around the fixed axis clockwise at a constant speed.
               In spinning-elevation two-axis tracking, the spinning axis serves as
            the fixed axis pointing to the target location, with the elevation axis