524  Dust Explosions in the Process Industries














             SPRING-LOADED
             COVER  FOR OPENIN
             GIVING ACCESS  TO
             CYLINDER





                                                         PAPER  SHEET  LINING
                                                         FOR  COLLECTING AND
                                                         WEIGHING  OF DUST
                                                         TRAPPED  IN TRAVERSING
                                           t CoMPRESSED   CYLINDER


             Figure 7.47  A 75 liter Nordtest Fire 0 7 7  vessel equipped with traversing cylinder for measuring local
             dust concentration in the vicinity of the ignition source (From Nordtest, 7 989).



                                                      +







                                                      CUP





















             Figure 7.48  Principle of Nordtest Fire 0 7 7  dust cloud sampling cylinder (b) compared with that of
             a simple cylindrical cup (a).