Page 193 - Estimators Piping Man Hour Manual
P. 193

176    Section Four—MECHANICAL     INSTRUMENTATION





                                    Local  Mounted


                                   MAN HOURS EACH



                                                                   Man Hours
                                                                      Each
        FT gauge pressure transmitter, pneumatic. Foxboro Model: 11GM.
        Range: spans from 10-2,000 psi with maximum range of 3,000 psi within
        limits  of range capsule,  maximum overrange 4,000 psi. Materials: 316 SS.
                       1
        Process Connection: A" or  /£* NPT female. Output Signal: 3-15  psi.
        Mounting: Bracket  for 2" pipe.  With air filter-regulator set and mounting
        bracket.                                                      7.6
        PT absolute pressure transmitter, pneumatic.  Foxboro  Model: HAH.
        Range Capsule:  20-200 psi,  adjustable  span, maximum overrange 350
                                          l
        psi. Body Material: 316 SS. Process Connection: /i'  NPT female. Output
        Signal: 3-15  psi. Mounting: Bracket for 2" pipe. With air  filter-regulator
        set and mounting bracket.
        PTI pressure indicating transmitter, pneumatic indicating.
        FoxboroModel: 45P. Case: Rectangular. Range: 0-10 to 0-2,000 psi.
        Scale: Eccentric, 6-/6" length. Output Signal: 3-15 psi. Pressure Element:
        Cu-Ni-Mn, Diaphragm. With air filter-regulator set and mounting yoke.
        PR pressure recorder direct connected. Foxboro  Model: 40PR.
        Case: Rectangular. Mounting: Yoke, Chart Drive: Electric,  115 volts, 60 Hz.,
        24-hour. Range: 0-10  to 0-2,000 psi. Pen: One. Pressure Element:
        Cu-Ni-Mn, diaphragm. With mounting yoke.
        PC pressure controller, pneumatic, direct connected. Foxboro Model:
        43AP-FA4. Control Function: Proportional  plus reset. Prop. Band: 4-400%.
        Reset Time: 0.5-25 minutes.  Range: 0-10 to 0-2,000 psi. Element: Cu-Ni-Mn,
        Diaphragm. Scale: Eccentric.  Relay Action: Reversible, Set Point Knob:
        Internal. Output Gauge: 0-30  psi. Mounting: Bracket  for 2" pipe.
        With air filter-regulator set and mounting bracket.           15.2

      Above man hours include checking out of storage, calibrating, hauling to erection site, installing, testing, and  final
      checkout.
      Man hours do not include connections to process and air signal lines. See piping accounts for these  charges,
      Man hours do not. include wiring for recorder electric  charge drive. See Electrical Man Hour Manual  for this charge.
   188   189   190   191   192   193   194   195   196   197   198